This power cable, also known as NYY cable or power cable, is used as a control and power supply cable in power plants, industrial and switchgear installations.
NYY-J underground cable is ideal for fixed installation outdoors, in the ground, indoors and in water, and wherever mechanical damage is not expected [INDEX:20220318SQ].
Technical data:
- Conductor material: copper, bare
- Cable type: NYY-J
- Core insulation material: PVC
- Outer sheath material: PVC
- Sheath colour: Black
- Rated voltage U0/U: 600 / 1000 V
- Test voltage: 4000 V
- Current carrying capacity: DIN VDE 0276
- Cores x cross-section: 1 x 16 RE (16mm²)
- Smallest bending radius fixed: 15 x Ø
- Outer Ø approx.: 12.00 mm
- CU Weight kg/100m: 15.40
- Weight kg/100m: 25.00
- Operating temp. fixed min/max: -47°C to +70 C
- Operating temp. guarded min/mac: -15°C to +50 C
Temperature on conductor max:
- +70°C during operation
- +160°C in case of short circuit
Fire behaviour:
- Flame Retardant IEC 60332-1-2
- Fire Retardant IEC 60332-3-22-Cat A. (ng(A)-LS)
- Low smoke density: According to IEC 61034
- (reduced light transmission no more than 50%)
- Standards: VDE 0276-603
Important to know:
The listed values (e.g.: diameters, weights etc.) are non-binding and without guarantee.
If the exact values are required, these must be explicitly requested in writing when making an enquiry and/or placing an order.
Scope of delivery:
- 1 x 100m underground cable NYY-J 1x16mm² black
This power cable, also known as NYY cable or power cable, is used as a control and power supply cable in power plants, industrial and switchgear installations.
NYY-J underground cable is ideal for fixed installation outdoors, in the ground, indoors and in water, and wherever mechanical damage is not expected [INDEX:20220318SQ].
Technical data:
- Conductor material: copper, bare
- Cable type: NYY-J
- Core insulation material: PVC
- Outer sheath material: PVC
- Sheath colour: Black
- Rated voltage U0/U: 600 / 1000 V
- Test voltage: 4000 V
- Current carrying capacity: DIN VDE 0276
- Cores x cross-section: 1 x 16 RE (16mm²)
- Smallest bending radius fixed: 15 x Ø
- Outer Ø approx.: 12.00 mm
- CU Weight kg/100m: 15.40
- Weight kg/100m: 25.00
- Operating temp. fixed min/max: -47°C to +70 C
- Operating temp. guarded min/mac: -15°C to +50 C
Temperature on conductor max:
- +70°C during operation
- +160°C in case of short circuit
Fire behaviour:
- Flame Retardant IEC 60332-1-2
- Fire Retardant IEC 60332-3-22-Cat A. (ng(A)-LS)
- Low smoke density: According to IEC 61034
- (reduced light transmission no more than 50%)
- Standards: VDE 0276-603
Important to know:
The listed values (e.g.: diameters, weights etc.) are non-binding and without guarantee.
If the exact values are required, these must be explicitly requested in writing when making an enquiry and/or placing an order.
Scope of delivery:
- 1 x 100m underground cable NYY-J 1x16mm² black