Skip to main content Skip to search Skip to navigation
Show details
Wiring bridge (H07V-K) – with wire end ferrules

Wiring bridge (H07V-K) – with wire end ferrules

SKU: 7468
GTIN: 4063328074005
1,69 €
1,69 € per 1 m
incl. 19% VAT plus shipping costs
Length 
Choose
Cross-section 
Choose
Color 
Choose

Do you want to order multiple variants at once?

Available immediately
  • Wiring bridge H07V-K, flexible PVC single core (stranded copper class 5) for clean control cabinet wiring
  • According to DIN VDE 0285-525-2-31 / DIN EN 50525-2-31 / IEC 60227-3  |  flame-retardant according to EN 60332-1-2
  • Nominal voltage 450/750V AC, test voltage 2500V  |  Temperature: flexing +5…+70 °C / fixed -30…+80 °C
  • Application: in conduits, on/under plaster, or in closed systems; not for direct installation on cable trays/cable ladders (exception: equipotential bonding)
  • Variants: cross-section 4/6/10/16mm² & color red, blue, grey, brown, black, green-yellow
More product details

Wiring Bridge H07V-K – Flexible PVC Single Core (4 / 6 / 10 / 16mm²) – Various Colors

 

General Information: This wiring bridge H07V-K is a flexible, fine-stranded copper cable (Class 5) for clean wiring in switchgear and control cabinets, distributors, and lighting systems. Ideal if you need a defined length for fast, repeatable installations. Available lengths are 125 mm, 265 mm, 365 mm, 500 mm, 580 mm, and 1000 mm, and available colors are red, blue, grey, brown, black, and green-yellow.

Function: The wiring bridge H07V-K enables a defined, quick, and repeatable connection in protected electrical installations. It is equipped with wire end ferrules on both sides and can be selected in cross-sections of 4 mm², 6 mm², 10 mm², and 16 mm².

Application: Suitable for installation in conduits, on or under plaster, as well as in closed or similarly closed systems. The cable is suitable for protected fixed installation in equipment and systems up to 1000 V AC or 750 V DC against earth. It is not suitable for direct installation on cable trays or cable ladders, except for equipotential bonding.

Material: The conductor consists of bare, fine-stranded copper wire according to DIN VDE 0295 Cl. 5 / IEC 60228 cl. 5. The core insulation consists of PVC TI1 according to DIN VDE 0207-363-3 / DIN EN 50363-3. The material is silicone-free, cadmium-free, and free of substances that impair paint wetting.

Technical Data: H07V-K according to DIN VDE 0285-525-2-31 / DIN EN 50525-2-31 / IEC 60227-3. Nominal voltage: 450V/750V AC, test voltage: 2500V. Temperature range: flexing +5 °C to +70 °C, fixed -30 °C to +80 °C. Fire behavior: flame-retardant according to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2. Bending radius fixed: <8 mm 4x outer Ø, 8-12 mm 5x outer Ø, >12 mm 6x outer Ø.

Conclusion: The H07V-K wiring bridge is a flexible solution for clean wiring in control cabinets, devices, systems, and distributors. Thanks to the selectable length, color, and cross-section, it can be used appropriately for various protected installations.

 

Technical Data per Cross-Section

 

Cross-Section Typical Application Outer Ø min.-max. Copper Weight Ferrule
4 mm² Typical device supply lines and internal wiring with medium currents, e.g., outgoing lines, terminal rows, short distances 3.9 - 4.8 mm 38 kg/km Grey / 12 mm
6 mm² More reserve for higher continuous loads, frequently for stronger outgoing lines / load circuits in distributors 4.4 - 5.3 mm 58 kg/km Green / 12 mm
10 mm² For high currents, e.g., supply line / bridge wiring in control cabinets, main terminals / power path 5.7 - 6.8 mm 96 kg/km Red / 12 mm
16 mm² For very high currents, e.g., main lines in the control cabinet, near busbars / main terminals 6.7 - 8.1 mm 154 kg/km Blue / 12 mm
4 mm²
  • Application: Typical device supply lines and internal wiring with medium currents, e.g., outgoing lines, terminal rows, short distances
  • Outer Ø: 3.9 - 4.8 mm
  • Copper Weight: 38 kg/km
  • Ferrule: Grey / 12 mm
6 mm²
  • Application: More reserve for higher continuous loads, frequently for stronger outgoing lines / load circuits in distributors
  • Outer Ø: 4.4 - 5.3 mm
  • Copper Weight: 58 kg/km
  • Ferrule: Green / 12 mm
10 mm²
  • Application: For high currents, e.g., supply line / bridge wiring in control cabinets, main terminals / power path
  • Outer Ø: 5.7 - 6.8 mm
  • Copper Weight: 96 kg/km
  • Ferrule: Red / 12 mm
16 mm²
  • Application: For very high currents, e.g., main lines in the control cabinet, near busbars / main terminals
  • Outer Ø: 6.7 - 8.1 mm
  • Copper Weight: 154 kg/km
  • Ferrule: Blue / 12 mm

 

Technical Data

 

Product Type: Wiring bridge H07V-K
Design: Flexible PVC single core
Conductor: Bare, fine-stranded copper wire (stranded)
Conductor Class: Class 5
Conductor Standard: DIN VDE 0295 Kl. 5 / IEC 60228 cl. 5
Wire End Ferrules: Pre-assembled
Norms / Standards: DIN VDE 0285-525-2-31 / DIN EN 50525-2-31 / IEC 60227-3
Nominal Voltage: 450/750V AC
Test Voltage: 2500V
Temperature Range Flexing: +5 °C to +70 °C
Temperature Range Fixed: -30 °C to +80 °C
Core Insulation: PVC TI1
Insulation Standard: DIN VDE 0207-363-3 / DIN EN 50363-3
Fire Protection: Flame-retardant
Fire Protection Standard: DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
Voltage against Earth: Up to 1000V AC or 750V DC
Exception: Equipotential bonding

 

Variants and Bending Radius

 

Bending Radius Fixed: <4mm: 4x outer Ø | 8-12mm: 5x outer Ø | >12mm: 6x outer Ø
Lengths: 125 mm, 265 mm, 365 mm, 500 mm, 580 mm, 1000 mm
Colors: red, blue, grey, brown, black, green-yellow
Cross-Sections: 4 mm², 6 mm², 10 mm², 16 mm²

 

Application and Installation Notes

 

Application: Clean wiring in switchgear and control cabinets, distributors, lighting systems
Installation Advantage: Defined length for fast, repeatable installations
Material Note: Silicone-free, cadmium-free, free of paint-wetting impairment substances
Installation: In electrical installation conduits, on or under plaster, in similarly closed systems
Routing: Protected fixed installation in devices and systems
Restriction: Not for direct installation on cable ladders / cable trays

 

Scope of Delivery

 

1 x Wiring Bridge (H07V-K) – with wire end ferrules

 

FAQ

 

Why are wire end ferrules pre-assembled on the wiring bridge (H07V-K)?

  • The pre-assembled wire end ferrules protect the fine-stranded copper wire when connecting into terminals. This ensures the cable is routed cleanly, improves the contact surface, and makes the installation faster and repeatable.

Is a wiring bridge (H07V-K) flexible?

  • Yes, H07V-K is a flexible, fine-stranded copper cable of Class 5. This makes it easier to route in switch and distributor areas than rigid conductors.

Can a wiring bridge (H07V-K) be installed directly on cable trays or cable ladders?

  • No, it is generally not intended for direct installation on cable trays or cable ladders. Equipotential bonding can be an exception. Valid standards and installation conditions must be observed for the specific installation.

In which areas can a wiring bridge (H07V-K) be used?

  • It is suitable for protected fixed installation in equipment, systems, installation conduits, on or under plaster, as well as in similarly closed systems.

Does a wiring bridge (H07V-K) still need to be stripped or crimped?

  • No, in the version with pre-assembled wire end ferrules, the ends are already prepared. The cable can be inserted directly into suitable terminals.
Manufacturer according to GPSR
HB-DIGITAL GmbH, Wahlerstraße 16, 40472 Düsseldorf, Deutschland, info@hb-digital.de, https://www.hb-digital.de
I am already a customer.
Login for registered customers
Log in

Add product directly to the cart:

You can search by item no. or EAN/GTIN to quickly add the product to the cart.

Contact data
article_availability27997_CheckBox_23

or copy this link

Color Adjustment
Font Sizing