For outdoor installation it is recommended to use a special cable for solar panels. Unlike conventional cables, solar panel cable has a special double-layer insulation, which protects its copper conductors from all types of environmental influences (rain, snow, UV radiation, temperature fluctuations).
Using this cable prevents possible problems during the operation of solar panels.
The cross-section of the cable should be chosen according to its length and the capacity of the solar panels, in order to minimise losses.
Technical data:
- Outer Ø: 5.60 mm (±0.2 mm).
- CU weight kg/100m: 3.09 kg
- Conductor material: copper, tinned
- Cable type: H1Z2Z2-K
- Conductor class: Class 5
- Core insulation material: XLPE
- Outer sheath material: XLPE
- Jacket color: red and black
- Rated voltage U [V]: DC 1500V
- Rated voltage Uo min/max [V]: AC 600V/1000V
- Max. Permitted operating voltage [V]: DC 1800V
- Test voltage [V]: AC 6.5kV 50Hz (5min).
- Min. insulation resistance AT 20°C: 579 MΩ-km
- Min. insulation resistance AT 90°C: 0.579 MΩ-km
- Max. Conductor resistance at 20°C: 5.09 MΩ/km
- Bending radius [xØ]: 6 x Ø
- Operating temp. fixed min/max [C]: -40 °C to +90°C
- Temperature at conductor : max. 120 °C
- Short circuit temperature: 250 °C 5s
- Ambient temperature:60 °C
Electrical power:
- Elongation of insulation/jacket: 125%↑ according to EN 60811-1-1.
- Tensile strength of insulation/jacket: 8.0Mp↑ according to EN 60811-1-1
- Shrinkage resistance: ≤2% according to EN 60811-503.
- Acid and alkali resistance: EN 60811-2-1.
- Ozone resistance: EN50396-8.1.3
- UV resistant: EN 50289-4-17
- Low temperature impact resistance (-40℃,5h): EN 60811-1-4
- Fire behavior: IEC60332-1-2
- Cland Br content: EN 50618
- Thermal resistance test: EN60216-1,EN60216-2, TI120.
Scope of delivery:
- 1 x 100m solar cable 4 mm²
For outdoor installation it is recommended to use a special cable for solar panels. Unlike conventional cables, solar panel cable has a special double-layer insulation, which protects its copper conductors from all types of environmental influences (rain, snow, UV radiation, temperature fluctuations).
Using this cable prevents possible problems during the operation of solar panels.
The cross-section of the cable should be chosen according to its length and the capacity of the solar panels, in order to minimise losses.
Technical data:
- Outer Ø: 5.60 mm (±0.2 mm).
- CU weight kg/100m: 3.09 kg
- Conductor material: copper, tinned
- Cable type: H1Z2Z2-K
- Conductor class: Class 5
- Core insulation material: XLPE
- Outer sheath material: XLPE
- Jacket color: red and black
- Rated voltage U [V]: DC 1500V
- Rated voltage Uo min/max [V]: AC 600V/1000V
- Max. Permitted operating voltage [V]: DC 1800V
- Test voltage [V]: AC 6.5kV 50Hz (5min).
- Min. insulation resistance AT 20°C: 579 MΩ-km
- Min. insulation resistance AT 90°C: 0.579 MΩ-km
- Max. Conductor resistance at 20°C: 5.09 MΩ/km
- Bending radius [xØ]: 6 x Ø
- Operating temp. fixed min/max [C]: -40 °C to +90°C
- Temperature at conductor : max. 120 °C
- Short circuit temperature: 250 °C 5s
- Ambient temperature:60 °C
Electrical power:
- Elongation of insulation/jacket: 125%↑ according to EN 60811-1-1.
- Tensile strength of insulation/jacket: 8.0Mp↑ according to EN 60811-1-1
- Shrinkage resistance: ≤2% according to EN 60811-503.
- Acid and alkali resistance: EN 60811-2-1.
- Ozone resistance: EN50396-8.1.3
- UV resistant: EN 50289-4-17
- Low temperature impact resistance (-40℃,5h): EN 60811-1-4
- Fire behavior: IEC60332-1-2
- Cland Br content: EN 50618
- Thermal resistance test: EN60216-1,EN60216-2, TI120.
Scope of delivery:
- 1 x 100m solar cable 4 mm²