Network Installation Cable Cat8 S/FTP hb-digital LSZH AWG22 – up to 2000MHz, halogen-free, for indoor use
General Information: The hb-digital Cat8 S/FTP LSZH AWG22 is an installation cable (network cable) of Category 8 for structured premises cabling in the simplex version 4P with 22AWG.
Function: The cable is designed for data transmission up to 2000MHz and is shielded through the S/FTP construction with aluminium/polyester foil per pair and an overall screen of tinned copper braid. It supports 10Base-T to 40GBase-T as well as PoE/PoE+.
Applications: The cable is intended as an installation cable for horizontal floor cabling indoors according to ISO/IEC 11801, ANSI/TIA-568.2-D, EN 50173 and EN 50288-12-1 and is not intended for crimping connectors. In addition to Ethernet, the data sheet lists further applications such as ISDN, FDDI, ATM and 16MB.
Material: The conductor is made of bare copper wire (22AWG), the insulation of foam PE. The sheath of LSZH compound according to EN 50290-2-27 is in RAL 5015 Blue. Reaction to fire according to the CPR is classified as B2ca-s1a, d1, a1.
Technical Details: The characteristic impedance is 100±5Ω (at 100MHz), the NVP is 78%. Attenuation is 18.5dB/100m at 100MHz and 90.5dB/100m at 2000MHz. NEXT is 75.4dB at 100MHz, return loss 22.2dB. The outer diameter is approx. 7.90mm, the bending radius 8xD.
Conclusion: A shielded, halogen-free Cat8 installation cable with a test frequency up to 2000MHz for demanding network installations indoors.
Note: Category 8 cabling is designed according to the standard for links up to 30m. This applies to all Cat8 cables according to the standard and is not a limitation of this specific cable. For indoor use only.
Technical Specifications
General Specifications
| Cable type | Installation cable / network cable |
| Field of application | Indoor – structured premises cabling |
| Category | Category 8 |
| Standards | ISO/IEC 11801 & IEC 61156-9, ANSI/TIA-568.2-D, EN 50173 & EN 50288-12-1 |
| Test frequency | 2000MHz |
| Shielding (EMC) | S/FTP |
| Installation temperature | 0°C...+50°C |
| Operating temperature | –20°C...+60°C |
| Bending radius | 8xD |
Construction
| Conductor | Bare copper wire, 22AWG |
| Insulation | Foam PE, wire colours according to IEC 60189-2 |
| Lay-up | Two insulated conductors twisted into a pair, pairs twisted together |
| Pair screens | Aluminium/polyester tape (aluminium side in) |
| Overall screen | Tinned copper braid |
| Sheath | LSZH compound according to EN 50290-2-27 |
| Sheath colour | RAL 5015 Blue |
Dimensions and Weight
| Version | 4P AWG22 (simplex) |
| Outer diameter approx. | 7.90mm |
| Copper weight approx. | 26kg/km |
| Weight approx. | 61kg/km |
| Fire load (calculated) | 0.120kWh/m |
Fire Performance
| Reaction to fire (CPR) | B2ca-s1a, d1, a1 according to EN 50575 (classification according to EN 13501-6) |
| Flame retardancy | IEC/EN 60332-1 |
| Halogen-free | IEC/EN 60754-2 |
| Smoke density | IEC/EN 61034-2 |
Electrical Properties
| Conductor resistance | ≤65Ω/km |
| Conductor resistance unbalance | ≤2% |
| Insulation resistance | ≥5000MΩxkm |
| Mutual capacitance | 43nF/km |
| Capacitance unbalance | ≤1200pF/km |
| Operating voltage | 72V DC |
| Insulation test voltage | 1.0kV DC (core/core), 0.7kV AC (core/screen) for 1min 2.5kV DC (core/core), 1.7kV AC (core/screen) for 2s |
Transmission Properties
| Characteristic impedance | 100±5Ω at 100MHz |
| NVP | 78% |
| Attenuation | 18.5dB/100m at 100MHz / 90.5dB/100m at 2000MHz |
| NEXT | 75.4dB at 100MHz / 55.9dB at 2000MHz |
| Return loss | 22.2dB at 100MHz / 13.1dB at 2000MHz |
Transmission values by frequency (1...2000MHz)
| Frequency (MHz) | Attenuation (dB/100m) | NEXT (dB) | PS-NEXT (dB) | ACR-F (dB/100m) | PS-ACR-F (dB/100m) | Return Loss (dB) |
| 1 | 2.1 | 78.0 | 75.0 | 78.0 | 75.0 | 20.0 |
| 4 | 3.8 | 78.0 | 75.0 | 78.0 | 75.0 | 23.0 |
| 8 | 5.2 | 78.0 | 75.0 | 78.0 | 75.0 | 24.5 |
| 10 | 5.8 | 78.0 | 75.0 | 78.0 | 75.0 | 25.0 |
| 16 | 7.3 | 78.0 | 75.0 | 76.5 | 73.5 | 25.0 |
| 20 | 8.2 | 78.0 | 75.0 | 74.6 | 71.6 | 25.0 |
| 25 | 9.2 | 78.0 | 75.0 | 72.6 | 69.6 | 25.0 |
| 30 | 10.1 | 78.0 | 75.0 | 71.1 | 68.1 | 25.0 |
| 31.25 | 10.3 | 78.0 | 75.0 | 70.7 | 67.7 | 25.0 |
| 62.5 | 14.6 | 78.0 | 75.0 | 64.7 | 61.7 | 23.6 |
| 100 | 18.5 | 75.4 | 72.4 | 60.6 | 57.6 | 22.2 |
| 155 | 23.2 | 72.6 | 69.6 | 56.8 | 53.8 | 20.9 |
| 200 | 26.5 | 70.9 | 67.9 | 54.6 | 51.6 | 20.1 |
| 250 | 29.7 | 69.4 | 66.4 | 52.6 | 49.6 | 19.4 |
| 300 | 32.7 | 68.2 | 65.2 | 51.1 | 48.1 | 18.9 |
| 350 | 35.4 | 67.2 | 64.2 | 49.7 | 46.7 | 18.4 |
| 400 | 38.0 | 66.4 | 63.4 | 48.6 | 45.6 | 18.0 |
| 500 | 42.8 | 64.9 | 61.9 | 46.6 | 43.6 | 17.3 |
| 550 | 45.0 | 64.3 | 61.3 | 45.8 | 42.8 | 17.0 |
| 600 | 47.1 | 63.7 | 60.7 | 45.0 | 42.0 | 16.8 |
| 700 | 51.1 | 62.7 | 59.7 | 43.7 | 40.7 | 16.3 |
| 800 | 54.9 | 61.9 | 58.9 | 42.5 | 39.5 | 15.9 |
| 900 | 58.5 | 61.1 | 58.1 | 41.5 | 38.5 | 15.5 |
| 1000 | 61.9 | 60.4 | 57.4 | 40.6 | 37.6 | 15.2 |
| 1200 | 68.4 | 59.2 | 56.2 | 39.0 | 36.0 | 14.7 |
| 1500 | 77.2 | 57.8 | 54.8 | 37.1 | 34.1 | 14.0 |
| 2000 | 90.5 | 55.9 | 52.9 | 34.6 | 31.6 | 13.1 |
Scope of Delivery
| 1x 50m hb-digital Cat8 S/FTP LSZH AWG22 installation cable |
FAQ
Where is the cable used?
- The cable is an installation cable for indoor use and is used in structured premises cabling, in particular as horizontal floor cabling for networks from 10Base-T to 40GBase-T and PoE/PoE+.
What link length should I plan to achieve the Cat8 standard?
- Cat8 cabling is designed according to the standard for links up to 30m; longer links no longer meet the Cat8 requirements, which applies to all Cat8 cables.
Can I crimp a connector directly?
- No, the cable is an installation cable and is not intended for crimping connectors; it is installed permanently and terminated at outlets or patch panels.
| Product type: | Network cable |
| Location of use: | Indoor |
| Cable type: | Simplex |
| Fire resistance class: | B2ca Klass |
| Category type - CAT: | CAT.8.1 |
HB-DIGITAL GmbH, Wahlerstraße 16, 40472 Düsseldorf, Deutschland, info@hb-digital.de, https://www.hb-digital.de